commercial lighting

Standards

> IK codes

 

Shock protection: IK Code. It is a code system to indicate the cover required protection level against harmful mechanical impacts. 


The IK code refers to the protection level. It is indicated as follows:
Each group of characteristic figures refers to the impact energy value, as indicated in the opposite table :


CODE IK0001020304050607080910
Shock energy (Joule)   0.15 0.20 0.35 0.50 0.70 1.00 2.00 5.00 10.00 20.00



> IP rating protection:


First number: protection degree against solid substances
Second number: protection against liquid substances


IP 20IP 40IP 54IP 65
Protected against solid substance over 12mm Protected against solid substance over 1mm Protected against dust
Protected against water splashings from all directions

Completely protected against dust
Protected against water splashings from all directions (0,3 bar of pressure to a distance of 3 meters)



> Class:


 CLASS 1CLASS 2CLASS 3
Main characteristics of the material Protection by earth connection Supplementary insulation but no means of protection by earth connection Used for power supply by extra low voltage of security (lower or equal in 50V)
Security precautions Connection to earth protection No necessary precaution Connection to extra low voltage of security (TBTS)